If you have been reading about stationary phase and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2026-01-13. Where a claim depends on a specific study, the study is described rather than over-claimed.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
| Property | Value | Notes |
|---|---|---|
| Abbreviation | HPLC | Also called high-performance liquid chromatography |
| Separation mechanism | Differential partitioning | Compounds distribute between mobile and stationary phases |
| Typical column chemistry | C18 (octadecylsilane) | Used in reversed-phase separations |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is common for trace and confirmatory work |
| Typical particle size | 1.8–5 µm | Smaller particles require higher pressure and can improve speed |
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
Adrenocortical hormones are considered steroid hormones because of the shared characteristic of a cholesterol backbone. The structures of different steroids differ by the types and locations of additional atoms on a cholesterol backbone. The cholesterol backbone consists of four hydrocarbon rings, three cyclohexane rings and one cyclopentane, that contribute to its insolubility in aqueous environments. However, the hydrophobic nature allows them to readily diffuse through the plasma membrane of cells. This is important to the function of steroid hormones as they rely on cellular response pathways to restore the homeostatic imbalance that initiated the hormone release.
The main method of treatment for potential death from signaling-related diseases involves either increasing or decreasing the susceptibility of apoptosis in diseased cells, depending on whether the disease is caused by either the inhibition of or excess apoptosis. For instance, treatments aim to restore apoptosis to treat diseases with deficient cell death and to increase the apoptotic threshold to treat diseases involved with excessive cell death. To stimulate apoptosis, one can increase the number of death receptor ligands (such as TNF or TRAIL), antagonize the anti-apoptotic Bcl-2 pathway, or introduce Smac mimetics to inhibit the inhibitor (IAPs). The addition of agents such as Herceptin, Iressa, or Gleevec works to stop cells from cycling and causes apoptosis activation by blocking growth and survival signaling further upstream. Finally, adding p53-MDM2 complexes displaces p53 and activates the p53 pathway, leading to cell cycle arrest and apoptosis. Many different methods can be used either to stimulate or to inhibit apoptosis in various places along the death signaling pathway. Apoptosis is a multi-step, multi-pathway cell-death programme that is inherent in every cell of the body. In cancer, the apoptosis cell-division ratio is altered. Cancer treatment by chemotherapy and irradiation kills target cells primarily by inducing apoptosis.
Wide range of genomic applications and scientific questions, including de novo genome assembly, haplotype phasing, structural variant analysis, and transcriptome and epigenetic analysis. Accuracy and scalability. Method requires small quantities of input DNA, which can be beneficial for small samples or single cell studies. More cost effective per sample in comparison with long-read technologies such as Oxford Nanopore sequencing. Libraries produced by linked-read can be processed using Illumina short read sequencing, increasing accessibility. Complexity of library construction - this technology requires high molecular DNA preparation in order to produce long enough DNA molecules for sequencing. Limitations in read length may result in limited haplotype resolution, which could reduce the efficacy of this technology in highly complex genomic regions.
ABS-201 is an AI-designed monoclonal antibody against the prolactin receptor (PRLR) currently in Phase 1/2a clinical trial for the treatment of androgenic alopecia (pattern hair loss) and endometriosis. It is taken by subcutaneous injection. ABS-201 is a possible first-in-class drug with a novel mechanism of action in the potential treatment of hair loss. ABS-201 is under development by Absci. It is believed that ABS-201 works by activating dormant hair follicles and causing them to move from the telogen phase to the anagen phase. In human ex vivo scalp model studies, ABS-201 stimulated hair regrowth, prolonged anagen phase, blocked catagen phase, inhibited telogen effluvium, and blocked hair from losing color. ABS-201 has been found to produce robust hair regrowth as compared with minoxidil in mice and balding macaques. The clinical trial for ABS-201 is being overseen by prominent hair loss researcher Rodney Sinclair, one of the principal investigators in minoxidil clinical trials. The chemical structure of the drug does not yet appear to have been disclosed.
DNA usually occurs as linear chromosomes in eukaryotes, and circular chromosomes in prokaryotes. The set of chromosomes in a cell makes up its genome; the human genome has approximately 3 billion base pairs of DNA arranged into 46 chromosomes. The information carried by DNA is held in the sequence of pieces of DNA called genes. Transmission of genetic information in genes is achieved via complementary base pairing. For example, in transcription, when a cell uses the information in a gene, the DNA sequence is copied into a complementary RNA sequence through the attraction between the DNA and the correct RNA nucleotides. Usually, this RNA copy is then used to make a matching protein sequence in a process called translation, which depends on the same interaction between RNA nucleotides. In an alternative fashion, a cell may copy its genetic information in a process called DNA replication. The details of these functions are covered in other articles; here the focus is on the interactions between DNA and other molecules that mediate the function of the genome.
Sources: en.wikipedia.org
Altria, like other tobacco companies, has invested in science and medical companies which develop and produce medical products for conditions caused or aggravated by smoking. As of 2024, Altria's three medical subsidiaries included the following: Cronos group (maker of recreational cannabis), Lexaria Bioscience (Developer of proprietary drug delivery technology, DehydraTECH, to improve active pharmaceutical ingredients entrance into the bloodstream) and Micreos (biotech company focused on discovering and developing recombinant proteins for chronic dermatology and oncology conditions). It has also designed and marketed electronic cigarettes. Altria launched the MarkTen and Green Smoke brands. Both of these were discontinued in December 2018. The company returned to this market through the acquisition of NJOY.
Analysis of Sulfolobus solfataricus CRISPRs revealed further complexities to the canonical model of spacer insertion, as one of its six CRISPR loci inserted new spacers randomly throughout its CRISPR array, as opposed to inserting closest to the leader sequence. Multiple CRISPRs contain many spacers to the same phage. The mechanism that causes this phenomenon was discovered in the type I-E system of E. coli. A significant enhancement in spacer acquisition was detected where spacers already target the phage, even mismatches to the protospacer. This 'priming' requires the Cas proteins involved in both acquisition and interference to interact with each other. Newly acquired spacers that result from the priming mechanism are always found on the same strand as the priming spacer. This observation led to the hypothesis that the acquisition machinery slides along the foreign DNA after priming to find a new protospacer.
Take breast cancer as an example. The sensitivity of traditional ultrasound screening for breast cancer can be 76%. While with the blood-based mRNA diagnostic method, the sensitivity could be 80.6%. mRNA-based disease diagnostic technologies allow quantitive measurement of mRNA in the certain samples, such as leukemia As some technologies such as RNA-seq can provide the entire transcriptome of individual, the mRNA-based disease diagnosis can be developed in the landscape of personalized medicine. In HER-2 breast cancer, detection of ERBB2 mRNA expression levels is helpful in predicting response to anti-HER2-based treatments. As mentioned above, the mRNA-based disease diagnostic technology is more sensitive and specific to certain diseases. Even though there is no obvious symptom, the mRNA-based disease diagnostic technology can serve as screening method for early changes in RNA levels. High serum metadherin mRNA expression was observed in colorectal cancer and associated with poorly differentiated histological grades
Chemistry... Key to Better Living. Diamond Jubilee Volume: A Record of Chemical Progress During the First 75 Years of the American Chemical Society. American Chemical Society. 1951. Skolnik, Herman; Reese, Kenneth M., eds. (1976). A Century of chemistry: the role of chemists and the American Chemical Society. Washington, D.C.: American Chemical Society. ISBN 978-0841203075. J. J. Bohning 2001. American Chemical Society Founded 1876. ACS, Washington, D.C. Reese, Kenneth M., ed. (2002). The American Chemical Society at 125: A recent history 1976–2001. American Chemical Society. ISBN 978-0-8412-3851-0. ACS website ACS Publications website ACS Chemical & Engineering News ACS Chemical Abstracts Service (CAS) International Year of Chemistry 2011(archived) A Cauldron Bubbles: PubChem and the American Chemical Society — Information Today, June 2005 ACS Chemical Biology WIKI(archived) ACS Chemical Biology Community(archived) ACS Green Chemistry Institute ACS Organic Division Leete Award Gassman Award
Sources: en.wikipedia.org
UR (Uitsluitend Recept): prescription only UA (Uitsluitend Apotheek): pharmacist only UAD (Uitsluitend Apotheek of Drogist): pharmacist or drugstore only AV (Algemene Verkoop): may be sold in general stores A drug that is UA may be sold OTC but only by pharmacists. The drug can be on the shelves like any other product. Examples are domperidone, 400 mg ibuprofen up to 50 tablets and dextromethorphan. A drug that is UAD can also be sold at drugstores which are stores where no prescription can be filled. The drugs are usually on the shelves, and the store also sells items like toys, gadgets, perfumes and homeopathic products. The drugs in this category have limited risk and addiction potential. Examples are naproxen and diclofenac in small amounts, cinnarizine, 400 mg ibuprofen up to 20 tablets and also 500 mg paracetamol up to 50 tablets. Drugs in the AV category can be sold at supermarkets, gas stations, etc. and include only drugs with minimal risk to the public, like paracetamol up to 20 tablets, 200 mg ibuprofen up to 10 tablets, cetirizine and loperamide.
Possibly the most common use of affinity chromatography is for the purification of recombinant proteins. Proteins with a known affinity are protein tagged in order to aid their purification. The protein may have been genetically modified so as to allow it to be selected for affinity binding; this is known as a fusion protein. Protein tags include hexahistidine (His), glutathione-S-transferase (GST), maltose binding protein (MBP), and the Colicin E7 variant CL7 tag. Histidine tags have an affinity for nickel, cobalt, zinc, copper and iron ions which have been immobilized by forming coordinate covalent bonds with a chelator incorporated in the stationary phase. For elution, an excess amount of a compound able to act as a metal ion ligand, such as imidazole, is used. GST has an affinity for glutathione which is commercially available immobilized as glutathione agarose. During elution, excess glutathione is used to displace the tagged protein. CL7 has an affinity and specificity for Immunity Protein 7 (Im7) which is commercially available immobilized as Im7 agarose resin. For elution, an active and site-specific protease is applied to the Im7 resin to release the tag-free protein.
Clustal Omega is a multiple sequence alignment (MSA) tool that enables to find an optimal alignment of at least three and maximum of 4000 input DNA and protein sequences. Clustal Omega algorithm employs two profile Hidden Markov models (HMMs) to derive the final alignment of the sequences. The output of the Clustal Omega may be visualized in a guide tree (the phylogenetic relationship of the best-pairing sequences) or ordered by the mutual sequence similarity between the queries. The main advantage of Clustal Omega over other MSA tools (Muscle, ProbCons) is its efficiency, while maintaining a significant accuracy of the results.
Sources: en.wikipedia.org
It measures the presence and amount of one or more compounds in a liquid sample. Separation occurs in a column, and detection produces a signal proportional to concentration. Identification usually requires comparison with a known reference standard under the same conditions.
In most cases the sample is consumed or altered during analysis, though some detectors are non-destructive. Fractions can be collected after separation for further study. Repeated testing therefore requires additional sample.
Run times range from under a minute for fast methods to over an hour for complex separations. Sample preparation, equilibration, and data review add time. Throughput depends on instrument configuration and method requirements.
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.